User manual Version 1.0
ABLELink
SW5001 Wireless Serial Server
19
[Main] [4 Serial Settings] [2 Baud rate]/ [3 Parity]/[4 Data bits]/ [5 Stop bits]/ [6 Flow control]
Here one may configure aliasbaud rateparitydata bitstop bit and the type of flow control defined by
the user,
Fig. 23. Serial Setting by Telnet
4.2.8. Configuring packet delimiter
Packet delimiter is a way of controlling the number of packets in a serial communication. It is designed to
keep packets in track. SW provides two ways in parameter setting: (1) Packet delimiter timer and (2)
Character patter terminator. By default, packet delimiter timer is 10 ms. The range of packet delimiter
timer is 10 to 30,000 msec, If “character pattern’ is selected, for a data stream ended with “0x0d0a”, then
the entire data buffer of the serial device is transmitted.
One may change packet delimiter timer follow the steps below.:
Configuring UART/Network Delimiter- Timer
One may choose packet delimiter timer’s value as the packet delimiter indicated in Figure below: